Biogas Generator


  • Min.Order Quantity: 1 unit
  • Supply Ability: 100 units per month
  • Product Detail

    CNPC

    DEUTZ

    MAN 50HZ

    MAN 60HZ

    MWM 50HZ

    MWM 60HZ

    Abstract

    Biogas generator set can not only turn waste into treasure, but also save money in a sense. In addition, the biogas generator set is environmentally friendly and will not pollute the environment.Compared with traditional generators, biogas generators have better power generation performance and lower power generation noise.

    TONTEK POWER biogas generator uses renewable energy biogas as the input fuel to generate clean energy: electricity and heat, and the comprehensive utilization  rate of energy. It involves a low investment cost and short recycling cycles. It guarantees the efficiency and independence of energy use. It is mainly used in  farms, food factories, industrial organic waste-water, agricultural straw, waste treatment plants and urban landfills.

    Main Features

    ●High quality components are selected from the top international manufacturers, with high reliability and perfect performance.

    ●The comprehensive utilization of biogas will help in reducing the greenhouse effect and promoting a various cycle of ecology. .

    ●The advanced intelligent control system can simultaneously monitor other main and auxiliary equipment in the biogas project to make the operation to be more safe and reliable.

    ● The set is durable and easy for maintenance.

    ● The set has strong environmental adaptability.

    ● Strong start-up capability at low temperature, high start-up success rate.

    ●Regulate power output and control exhaust emissions by monitoring combustion chamber temperature and knock.

    ● Low thermal load on biogas generator engines

    ● International advanced imported ignition module components makes the ignition energy more powerful and the combustion more sufficient, reduces the exhaust emissions, truly achieves energy saving and emission reduction

    ●Intelligent parallel machine control system can realize parallel operation of multiple units to meet the power demand of large load.

    ●All components of the generator set are carefully designed to operate in perfect coordination with the system for optimal performance and maximum efficiency.


  • Previous:
  • Next:

  • Model

    Rated

    Engine

    Rotation

    No.of

    Alternator

    dimension

    Weight

    Power

    Model

    Speed

    Cylinders

    Displace

    KW

    KVA

    190 & 300

    RPM

    & Type

    ment (L)

    Siemens Marathon or Equal

    (L*W*H)(mm)

    (kg)

    Series

    (50HZ/60HZ)

    EJ-250NB

    250

    313

    6190ZLT

    1000/1200

    6.L

    35.7

    1FC6 Series

    4950*1760*2200

    8750

    EJ-320NB

    320

    400

    G8V190ZLD

    1000/1200

    8.Vee

    47.6

    1FC6 Series

    4566*2040*2200

    10700

    •EJ-400NB

    400

    500

    12V190DT

    1000/1200

    12.Vee

    71.5

    1FC6 Series

    4566*2040*2200

    11500

    EJ-450NB

    450

    563

    12V190ZDT

    1000/1200

    12.Vee

    71.5

    1FC6 Series

    4790*2040*2212

    11800

    EJ-500B

    500

    625

    G12V190ZLDT

    1000/1200

    12.Vee

    71.5

    1FC6 Series

    5260*2040*2500

    12800

    •EZ-500NB

    500

    625

    6300D/T

    600/600

    6.L

    161

    1FC6 Series

    6400*1600*2900

    22000

    EJ-600NB

    600

    750

    G12V190ZLDT

    1000/1200

    12.Vee

    71.5

    1FC6 Series

    5260*2040*2500

    12600

    •EZ-600NB

    600

    750

    8300D/T-1

    500/500

    8.L

    215

    1FC6 Series

    6400*1600*2900

    22000

    •EZ-700NB

    700

    875

    8300D/T-2

    600/600

    8.L

    215

    1FC6 Series

    6400*1600*2900

    22000

    EJ-800NB

    800

    1000

    H16V190ZLT

    1000/1200

    16.Vee

    97.53

    1FC6 Series

    6070*2380*2776

    22000

    EJ-1000NB

    1000

    1250

    H16V190ZLT

    1000/1200

    16.Vee

    97.53

    1FC6 Series

    6070*2380*2776

    22000

    EZ-1000NB

    1000

    1250

    8300ZLD/T-1

    600/600

    8.L

    215

    1FC6 Series

    6400*1600*3100

    25000

    Remarks:

    • Model with “B” means for biogas; Model with “NB” means for both natural gas and biogas;

    • Model with “•” means engine air intake is naturally aspirated (without turbocharger and intercooler), which is suitable for low quality methane gas.

    • 50Hz & 60Hz are available, Various low Voltage and High Voltage of 3.3kV~13.8kV are available for options.

    • Special requirements for Soundproof Canopy/Container, ATS, Synchronizing Parallel Control panels and CHP are available for options.

    • The data herein is just for purpose of reference only and not binding. The data given in the official offer is decisive.

    Model

    Rated

    Engine

    Bore*Stroke

    Displace

    No.of

    Air Intake

    Overall

    Weight

    Power

    Model

    (mm)

    ment

    Cylinders

    Method

    dimension

    (kg)

    KW

    KVA

    (L)

    & Type

    (L*W*H)(mm)

    ED-50NB

    50

    63

    TBD226B

    105*130

    6.8

    6.L

    Natural

    2320*980*1450

    1050

    ED-60NB

    60

    75

    TBD226B

    105*130

    6.8

    6.L

    Natural

    2320*980*1450

    1100

    EST-80NB

    80

    100

    WD615

    126*130

    9.8

    6.L

    Natural

    2700*980*1680

    1900

    ED-80NB

    80

    100

    TBD226B

    105*130

    6.8

    6.L

    Turbo

    2550*1100*1450

    1250

    EST-100NB

    100

    125

    WD615

    126*130

    11.6

    6.L

    Natural

    2750*1080*1680

    2100

    ED-100NB

    100

    125

    BF6M1015

    132*145

    11.9

    6.Vee

    Natural

    2350*1200*1750

    1650

    EST-120NB

    120

    150

    WD615

    126*130

    9.8

    6.L

    Turbo

    2850*1100*1680

    2250

    ED-120NB

    120

    150

    BF6M1015

    132*145

    11.9

    6.Vee

    Natural

    2450*1200*1750

    1780

    EST-150NB

    150

    188

    WD618

    126*155

    11.6

    6.L

    Turbo

    3050*1100*1800

    2210

    ED-150NB

    150

    188

    BF6M1015

    132*145

    11.9

    6.Vee

    Turbo

    2600*1250*1750

    2150

    EST-200NB

    200

    250

    WD618

    126*155

    11.6

    6.L

    Turbo

    3050*1100*1800

    2320

    ED-200NB

    200

    250

    BF6M1015

    132*145

    11.9

    6.Vee

    Turbo

    2650*1460*1880

    2250

    ED-250NB

    250

    313

    BF8M1015

    132*145

    15.9

    8.Vee

    Turbo

    3000*1550*1950

    2650

    ★Remarks:

    • Low voltage of 380V/400V/415V/440V/480V/690V, High Voltage of 6.3KV/10.5KV and other special voltages are available.

    • Special requirements for Soundproof Canopy/Container, ATS, Synchronizing Parallel panels and CHP are available for your options.

    • Above power ratings are based on natural gas (PNG, LNG, CNG). For other gas types such as biogas, oilfield associated Gas and Coalmine Gas etc., the engine power rating will be adjusted according to the exact gas quality.

    • The data herein can vary depending on individual production requirements or due to improved technology.

    Model

    COP

    Engine

    Engine

    Alternator

    Configuration

    Elec. Eff.

    Heat Eff.

    Tot. Eff.

    dimension

    Weight

    Model

    Power

    KW

    MAN

    KW

    Leroy Somer or Equal

    (L*W*H)(mm)

    (kg)

    EM-66B5

    66

    E0834LE302

    68

    LSA Series

    L4

    38.30%

    52.00%

    90.2%

    2800*1050*1550

    1800

    EM-100B5

    100

    E0836LE202

    110

    LSA Series

    L6

    36.50%

    49.30%

    85.80%

    3700*1150*1750

    2200

    EM-200B5

    200

    E2876LE202

    220

    LSA Series

    L6

    36.70%

    46.80%

    83.5%

    4300*1300*2000

    4400

    EM-220B5

    220

    E2676LE212

    252

    LSA Series

    L6

    40.20%

    49.10%

    89.30%

    4300*1300*2000

    4600

    EM-250B5

    250

    E2848LE322

    265

    LSA Series

    V8

    38.10%

    49.60%

    87.70%

    4300*1300*2000

    EM-350B5

    350

    E3268LE222

    370

    LSA Series

    V8

    39.30%

    50.50%

    89.80%

    5200*2000*2100

    6600

    EM-400B5

    400

    E2842LE202

    420

    LSA Series

    V12

    38.10%

    50.30%

    88.40%

    5200*2000*2100

    6400

    EM-450B5

    450

    E3262LE232

    500

    LSA Series

    V12

    40.10%

    48.90%

    89.00%

    5500*2000*2100

    7500

    EM-520B5

    520

    E3262LE202

    550

    LSA Series

    V12

    38.30%

    48.20%

    86.50%

    5200*2000*2100

    ★Remarks:

    • Above Gensets Models are based on AC Voltage of 400/230V and 480V/270V, Other special low Voltages.

    • Above data is based on gas HV 20.4MJ/ Nm³; Power Factor Cosφ=1; Exhaust Temperature decreased to 120℃; Heat Value Tolerance 8%, Output Power Tolerance 5%.

    • NOx Emissions Level <500mg/m3 . Special requirements for emissions data such as EPA Standard can be realized by adding SCR and CO Catalyst.

    • Engine Overhaul Time is around 50000~60000 hours.

    • Wrranty terms: 15 Months after delivery , 12 Months after Installment or 8000 hours accumulated running time, which is subject to the earlier one.

    • The data herein is just for purpose of reference only and not binding. The data given in the official offer is decisive.

    Model

    COP

    Engine

    Engine

    Alternator

    Configuration

    Elec. Eff.

    Heat Eff.

    Tot. Eff.

    dimension

    Weight

    Model

    Power

    KW

    MAN

    KW

    Leroy Somer or Equal

    (L*W*H)(mm)

    (kg)

    EM-66B6

    66

    E0834LE302

    68

    LSA Series

    L4

    37.20%

    52.50%

    89.60%

    2800*1050*1550

    1800

    EM-100B6

    100

    E0836LE202

    110

    LSA Series

    L6

    35.10%

    53.70%

    88.80%

    3700*1150*1750

    2200

    EM-180B6

    180

    E2876LE302

    200

    LSA Series

    L6

    34.60%

    50.80%

    85.40%

    4300*1300*2000

    4400

    EM-220B6

    220

    E2676LE212

    250

    LSA Series

    L6

    40.30%

    46.40%

    86.70%

    4300*1300*2000

    4600

    EM-250B6

    250

    E2848LE322

    295

    LSA Series

    V8

    35.70%

    51.30%

    87.00%

    4300*1300*2000

    4600

    EM-390B6

    390

    E3268LE222

    420

    LSA Series

    V8

    37.50%

    50.50%

    88.00%

    5200*2000*2100

    6600

    EM-420B6

    420

    E2842LE322

    462

    LSA Series

    V12

    38.40%

    52.30%

    90.70%

    5500*2000*2100

    7500

    EM-560B6

    560

    E3262LE202

    580

    LSA Series

    V12

    37.40%

    51.50%

    88.9%

    3300*1700*1600

    3300

    ★Remarks:

    • Above Gensets Models are based on AC Voltage of 400/230V and 480V/270V, Other special low Voltages.

    • Above data is based on gas HV 20.4MJ/ Nm³; Power Factor Cosφ=1; Exhaust Temperature decreased to 120℃; Heat Value Tolerance 8%, Output Power Tolerance 5%.

    • NOx Emissions Level <500mg/m3 . Special requirements for emissions data such as EPA Standard can be realized by adding SCR and CO Catalyst.

    • Engine Overhaul Time is around 50000~60000 hours.

    • Wrranty terms: 15 Months after delivery , 12 Months after Installment or 8000 hours accumulated running time, which is subject to the earlier one.

    • The data herein is just for purpose of reference only and not binding. The data given in the official offer is decisive.

    Model

    COP

    Engine

    Bore*Stroke

    Displace

    Ratation

    Elec.

    Therm.

    Total

    dimension

    Weight

    (KW)

    Model

    (mm)

    ment

    Speed

    Eff.

    Eff.

    Eff.

    (L)

    (rpm)

    (%)

    (%)

    (%)

    (L*W*H)(mm)

    (KG)

    EMW-400B5

    400

    TCG2016V08C /

    132*160

    17.5

    1500

    42.8

    42.1

    84.9

    3090*1490*2190

    5340

    CG132-8

    EMW-600B5

    600

    TCG2016V12C /

    132*160

    26.3

    1500

    42.7

    42.3

    85

    3690*1490*2190

    7000

    CG132-12

    EMW-800B5

    800

    TCG2016V16C /

    132*160

    35

    1500

    42.8

    42.3

    85.1

    4090*1590*2190

    8450

    CG132-16

    EMW-1200B5

    1200

    TCG2020V12 /

    170*195

    53.1

    1500

    42

    43.8

    85.8

    4790*1810*2210

    11700

    CG170-12

    EMW-1560B5

    1560

    TCG2020V16 /

    170*195

    70.8

    1500

    41.7

    44

    85.7

    5430*1810*2210

    13320

    CG170-16

    EMW-2000B5

    2000

    TCG2020V20 /

    170*195

    88.5

    1500

    42.9

    43.3

    86.2

    6200*1710*2190

    17900

    CG170-20

    EMW-3770B5

    3770

    TCG2032V16 /

    260*320

    271.8

    1000

    43

    39.9

    82.9

    9200*2690*3390

    51200

    CG260-16

    ★Remarks:

    • Above engine marked “•” version optimized for island operation and load compensation.

    • Above engine marked “♦” means optimized efficiency version.

    • Transport dimensions for gensets; components set up separately must be taken into consideration.

    • According to ISO 3046/1 at U=0.4 kV,cos=1.0 for 50 Hz and methane number of MN-70 (MN-80 for some engine models) for natural gas.

    • Exhaust gas cooled to 120°C for natural gas and 150°C (TCG2032 180°C) for biogas.

    • NO ≤ 500 mg/Nm³; exhaust gas dry at 5 % O2.

    • Data for special gas and dual gas operation on request.

    Model

    COP

    Engine

    Bore*Stroke

    Displace

    Ratation

    Elec.

    Therm. E

    Total

    dimension

    Weight

    (KW)

    Model

    (mm)

    ment

    Speed

    Eff.

    ff.

    Eff.

    (L)

    (rpm)

    (%)

    (%)

    (%)

    (L*W*H)(mm)

    (kg)

    EMW-400B6

    400

    TCG2016V08C /

    132*160

    17.5

    1800

    41.6

    43.2

    84.8

    3170*1490*2190

    5120

    CG132-8

    EMW-600B6

    600

    TCG2016V12C /

    132*160

    26.3

    1800

    41.4

    43.7

    85.1

    3770*1490*2190

    6260

    CG132-12

    EMW-800B6

    800

    TCG2016V16C /

    132*160

    35

    1800

    41.7

    43.3

    85

    4130*1490*2190

    6780

    CG132-16

    EMW-1200B6

    1200

    TCG2020V12 /

    170*195

    53.1

    1500

    41.8

    43.8

    85.6

    5970*1790*2210

    12850

    CG170-12

    EMW-1560B6

    1560

    TCG2020V16 /

    170*195

    70.8

    1500

    41.4

    43.9

    85.3

    6640*1790*2210

    14850

    CG170-16

    EMW-2000B6

    2000

    TCG2020V20 /

    170*195

    88.5

    1500

    42.6

    43.3

    85.9

    7470*1710*2190

    19400

    CG170-20

    EMW-3510B6

    3510

    TCG2032V16 /

    260*320

    271.8

    900

    43.3

    38.5

    81.8

    9420*2690*3390

    53300

    CG260-16

    ★Remarks:

    • Above engine marked “•” version optimized for island operation and load compensation.

    • Above engine marked “♦” means optimized efficiency version.

    • Transport dimensions for gensets; components set up separately must be taken into consideration.

    • According to ISO 3046/1 at U=0.4 kV,cos=1.0 for 50 Hz and methane number of MN-70 (MN-80 for some engine models) for natural gas.

    • Exhaust gas cooled to 120°C for natural gas and 150°C (TCG2032 180°C) for biogas.

    • NO ≤ 500 mg/Nm³; exhaust gas dry at 5 % O2.

    • Data for special gas and dual gas operation on request.

    Related Products