Sewage Gas Generator
Abstract
Sewage gas is produced by anaerobic decomposition of organic materials.The main significance of sewage gas power generation has two aspects. One is energy conservation and emission reduction. There are tens of thousands of tons of sewage each year, generating a lot of gas. The waste gas is collected centrally to prevent pollution emissions. Power generation from the gas produced by waste fermentation, making harmful gas waste to be used for power generation
TONTEK POWER sewage gas generator can run with highly steady and excellent performance. It has much longer life-span and very economic in price based on wonderful quality. High power density reduces installation size and costs, and low vibration has almost no impact on the surrounding environments. It is easy for maintenance and operation. The main application is power stations,construction sites, mining and other situations.
Main Features
●High quality components are selected from the top international manufacturers, with high reliability and perfect performance.
● The maintenance cost is low and the repair cycle is long .
● The controller has a historical operation recording function for troubleshooting and inspection.
● Rugged structure ensures lowest vibration.
● Perfect electrical efficiency, use sewage to generate more electricity and reduce purchases from the grid.
● Extremely high reliability with minimal maintenance costs.
● Use unique hoisting design, external paint process, with high function of anti-rust and anti-corrosion.
● All components of the generator set are carefully designed to work perfectly with the system for optimal performance and maximum efficiency.
● Help for reducing the greenhouse effect and promoting multiple ecological cycles.
● Modular structure design can be quickly installed and put into use.
● Good start-up performance and high start-up success rate.
●The set is durable, runs safely and stably, and has strong environmental adaptability.
● Special design set for longer overhaul time.
Model |
Rated |
Engine |
Rotation |
No.of Cylinders& Type |
Displace |
Alternator |
Overall |
Weight |
|
Power |
Model |
Speed |
dimension |
(kg) |
|||||
kW |
kVa |
190 & 300 |
RPM |
ment (L) |
Siemens |
(L*W*H)(mm) |
|||
Series |
(50HZ/60HZ) |
Marathon |
|||||||
or Equal |
|||||||||
EJ-250NB |
250 |
313 |
6190ZLT |
1000/1200 |
6.L |
35.7 |
1FC6 Series |
4950*1760*2200 |
8750 |
EJ-320NB |
320 |
400 |
G8V190ZLD |
1000/1200 |
8.Vee |
47.6 |
1FC6 Series |
4566*2040*2200 |
10700 |
•EJ-400NB |
400 |
500 |
12V190DT |
1000/1200 |
12.Vee |
71.5 |
1FC6 Series |
4566*2040*2200 |
11500 |
EJ-450NB |
450 |
563 |
12V190ZDT |
1000/1200 |
12.Vee |
71.5 |
1FC6 Series |
4790*2040*2212 |
11800 |
EJ-500B |
500 |
625 |
G12V190ZLDT |
1000/1200 |
12.Vee |
71.5 |
1FC6 Series |
5260*2040*2500 |
12800 |
•EZ-500NB |
500 |
625 |
6300D/T |
600/600 |
6.L |
161 |
1FC6 Series |
6400*1600*2900 |
22000 |
EJ-600NB |
600 |
750 |
G12V190ZLDT |
1000/1200 |
12.Vee |
71.5 |
1FC6 Series |
5260*2040*2500 |
12600 |
•EZ-600NB |
600 |
750 |
8300D/T-1 |
500/500 |
8.L |
215 |
1FC6 Series |
6400*1600*2900 |
22000 |
•EZ-700NB |
700 |
875 |
8300D/T-2 |
600/600 |
8.L |
215 |
1FC6 Series |
6400*1600*2900 |
22000 |
EJ-800NB |
800 |
1000 |
H16V190ZLT |
1000/1200 |
16.Vee |
97.53 |
1FC6 Series |
6070*2380*2776 |
22000 |
EJ-1000NB |
1000 |
1250 |
H16V190ZLT |
1000/1200 |
16.Vee |
97.53 |
1FC6 Series |
6070*2380*2776 |
22000 |
EZ-1000NB |
1000 |
1250 |
8300ZLD/T-1 |
600/600 |
8.L |
215 |
1FC6 Series |
6400*1600*3100 |
25000 |
★Remarks:
• Model with “B” means for biogas; Model with “NB” means for both natural gas and biogas;
• Model with “•” means engine air intake is naturally aspirated (without turbocharger and intercooler), which is suitable for low quality methane gas.
• 50Hz & 60Hz are available, Various low Voltage and High Voltage of 3.3kV~13.8kV are available for options.
• Special requirements for Soundproof Canopy/Container, ATS, Synchronizing Parallel Control panels and CHP are available for options.
• The data herein is just for purpose of reference only and not binding. The data given in the official offer is decisive.
Model |
Rated |
Engine |
Bore*Stroke |
Displace |
No.of Cylinders& Type |
Air Intake |
Overall |
Weight |
|
Power |
Model |
(mm) |
ment |
Method |
dimension |
(kg) |
|||
KW |
KVA |
(L) |
(L*W*H)(mm) |
||||||
ED-50NB |
50 |
63 |
TBD226B |
105*130 |
6.8 |
6.L |
Natural |
2320*980*1450 |
1050 |
ED-60NB |
60 |
75 |
TBD226B |
105*130 |
6.8 |
6.L |
Natural |
2320*980*1450 |
1100 |
EST-80NB |
80 |
100 |
WD615 |
126*130 |
9.8 |
6.L |
Natural |
2700*980*1680 |
1900 |
ED-80NB |
80 |
100 |
TBD226B |
105*130 |
6.8 |
6.L |
Turbo |
2550*1100*1450 |
1250 |
EST-100NB |
100 |
125 |
WD615 |
126*130 |
11.6 |
6.L |
Natural |
2750*1080*1680 |
2100 |
ED-100NB |
100 |
125 |
BF6M1015 |
132*145 |
11.9 |
6.Vee |
Natural |
2350*1200*1750 |
1650 |
EST-120NB |
120 |
150 |
WD615 |
126*130 |
9.8 |
6.L |
Turbo |
2850*1100*1680 |
2250 |
ED-120NB |
120 |
150 |
BF6M1015 |
132*145 |
11.9 |
6.Vee |
Natural |
2450*1200*1750 |
1780 |
EST-150NB |
150 |
188 |
WD618 |
126*155 |
11.6 |
6.L |
Turbo |
3050*1100*1800 |
2210 |
ED-150NB |
150 |
188 |
BF6M1015 |
132*145 |
11.9 |
6.Vee |
Turbo |
2600*1250*1750 |
2150 |
EST-200NB |
200 |
250 |
WD618 |
126*155 |
11.6 |
6.L |
Turbo |
3050*1100*1800 |
2320 |
ED-200NB |
200 |
250 |
BF6M1015 |
132*145 |
11.9 |
6.Vee |
Turbo |
2650*1460*1880 |
2250 |
ED-250NB |
250 |
313 |
BF8M1015 |
132*145 |
15.9 |
8.Vee |
Turbo |
3000*1550*1950 |
2650 |
★Remarks:
• Low voltage of 380V/400V/415V/440V/480V/690V, High Voltage of 6.3KV/10.5KV and other special voltages are available.
• Special requirements for Soundproof Canopy/Container, ATS, Synchronizing Parallel panels and CHP are available for your options.
• Above power ratings are based on natural gas (PNG, LNG, CNG). For other gas types such as biogas, oilfield associated Gas and Coalmine Gas etc., the engine power rating will be adjusted according to the exact gas quality.
• The data herein can vary depending on individual production requirements or due to improved technology.
Model |
COP |
Engine |
Engine |
Alternator |
Configuration |
Elec. Eff. |
Heat Eff. |
Tot. Eff. |
Overall |
Weight |
Model |
Power |
dimension |
(kg) |
|||||||
KW |
MAN |
KW |
Leroy Somer |
(L*W*H)(mm) |
||||||
or Equal |
||||||||||
EM-66B5 |
66 |
E0834LE302 |
68 |
LSA Series |
L4 |
38.30% |
52.00% |
90.2% |
2800*1050*1550 |
1800 |
EM-100B5 |
100 |
E0836LE202 |
110 |
LSA Series |
L6 |
36.50% |
49.30% |
85.80% |
3700*1150*1750 |
2200 |
EM-200B5 |
200 |
E2876LE202 |
220 |
LSA Series |
L6 |
36.70% |
46.80% |
83.5% |
4300*1300*2000 |
4400 |
EM-220B5 |
220 |
E2676LE212 |
252 |
LSA Series |
L6 |
40.20% |
49.10% |
89.30% |
4300*1300*2000 |
4600 |
EM-250B5 |
250 |
E2848LE322 |
265 |
LSA Series |
V8 |
38.10% |
49.60% |
87.70% |
4300*1300*2000 |
4600 |
EM-350B5 |
350 |
E3268LE222 |
370 |
LSA Series |
V8 |
39.30% |
50.50% |
89.80% |
5200*2000*2100 |
6600 |
EM-400B5 |
400 |
E2842LE202 |
420 |
LSA Series |
V12 |
38.10% |
50.30% |
88.40% |
5200*2000*2100 |
6400 |
EM-450B5 |
450 |
E3262LE232 |
500 |
LSA Series |
V12 |
40.10% |
48.90% |
89.00% |
5500*2000*2100 |
7500 |
EM-520B5 |
520 |
E3262LE202 |
550 |
LSA Series |
V12 |
38.30% |
48.20% |
86.50% |
5200*2000*2100 |
7500 |
★Remarks:
• Above Gensets Models are based on AC Voltage of 400/230V and 480V/270V, Other special low Voltages.
• Above data is based on gas HV 20.4MJ/ Nm³; Power Factor Cosφ=1; Exhaust Temperature decreased to 120℃; Heat Value Tolerance 8%, Output Power Tolerance 5%.
• NOx Emissions Level <500mg/m3 . Special requirements for emissions data such as EPA Standard can be realized by adding SCR and CO Catalyst.
• Engine Overhaul Time is around 50000~60000 hours.
• Wrranty terms: 15 Months after delivery , 12 Months after Installment or 8000 hours accumulated running time, which is subject to the earlier one.
• The data herein is just for purpose of reference only and not binding. The data given in the official offer is decisive.
Model |
COP |
Engine |
Engine |
Alternator |
Configuration |
Elec. Eff. |
Heat Eff. |
Tot. Eff. |
Overall |
Weight |
Model |
Power |
dimension |
(kg) |
|||||||
KW |
MAN |
KW |
Leroy Somer |
(L*W*H)(mm) |
||||||
or Equal |
||||||||||
EM-66B6 |
66 |
E0834LE302 |
68 |
LSA Series |
L4 |
37.20% |
52.50% |
89.60% |
2800*1050*1550 |
1800 |
EM-100B6 |
100 |
E0836LE202 |
110 |
LSA Series |
L6 |
35.10% |
53.70% |
88.80% |
3700*1150*1750 |
2200 |
EM-180B6 |
180 |
E2876LE302 |
200 |
LSA Series |
L6 |
34.60% |
50.80% |
85.40% |
4300*1300*2000 |
4400 |
EM-220B6 |
220 |
E2676LE212 |
250 |
LSA Series |
L6 |
40.30% |
46.40% |
86.70% |
4300*1300*2000 |
4600 |
EM-250B6 |
250 |
E2848LE322 |
295 |
LSA Series |
V8 |
35.70% |
51.30% |
87.00% |
4300*1300*2000 |
4600 |
EM-390B6 |
390 |
E3268LE222 |
420 |
LSA Series |
V8 |
37.50% |
50.50% |
88.00% |
5200*2000*2100 |
6600 |
EM-420B6 |
420 |
E2842LE322 |
462 |
LSA Series |
V12 |
38.40% |
52.30% |
90.70% |
5500*2000*2100 |
7500 |
EM-560B6 |
560 |
E3262LE202 |
580 |
LSA Series |
V12 |
37.40% |
51.50% |
88.9% |
3300*1700*1600 |
3300 |
★Remarks:
• Above Gensets Models are based on AC Voltage of 400/230V and 480V/270V, Other special low Voltages.
• Above data is based on gas HV 20.4MJ/ Nm³; Power Factor Cosφ=1; Exhaust Temperature decreased to 120℃; Heat Value Tolerance 8%, Output Power Tolerance 5%.
• NOx Emissions Level <500mg/m3 . Special requirements for emissions data such as EPA Standard can be realized by adding SCR and CO Catalyst.
• Engine Overhaul Time is around 50000~60000 hours.
• Wrranty terms: 15 Months after delivery , 12 Months after Installment or 8000 hours accumulated running time, which is subject to the earlier one.
• The data herein is just for purpose of reference only and not binding. The data given in the official offer is decisive.
Model |
COP |
Engine |
Bore*Stroke |
Displace |
Ratation |
Elec. |
Therm. |
Total |
Overall |
Weight |
(KW) |
Model |
(mm) |
ment |
Speed |
Eff. |
Eff. |
Eff. |
dimension |
(kg) |
|
(L) |
(rpm) |
(%) |
(%) |
(%) |
(L*W*H)(mm) |
|||||
EMW-400B5 |
400 |
TCG2016V08C / |
132*160 |
17.5 |
1500 |
42.8 |
42.1 |
84.9 |
3090*1490*2190 |
5340 |
CG132-8 |
||||||||||
EMW-600B5 |
600 |
TCG2016V12C / |
132*160 |
26.3 |
1500 |
42.7 |
42.3 |
85 |
3690*1490*2190 |
7000 |
CG132-12 |
||||||||||
EMW-800B5 |
800 |
TCG2016V16C / |
132*160 |
35 |
1500 |
42.8 |
42.3 |
85.1 |
4090*1590*2190 |
8450 |
CG132-16 |
||||||||||
EMW-1200B5 |
1200 |
TCG2020V12 / |
170*195 |
53.1 |
1500 |
42 |
43.8 |
85.8 |
4790*1810*2210 |
11700 |
CG170-12 |
||||||||||
EMW-1560B5 |
1560 |
TCG2020V16 / |
170*195 |
70.8 |
1500 |
41.7 |
44 |
85.7 |
5430*1810*2210 |
13320 |
CG170-16 |
||||||||||
EMW-2000B5 |
2000 |
TCG2020V20 / |
170*195 |
88.5 |
1500 |
42.9 |
43.3 |
86.2 |
6200*1710*2190 |
17900 |
CG170-20 |
||||||||||
EMW-3770B5 |
3770 |
TCG2032V16 / |
260*320 |
271.8 |
1000 |
43 |
39.9 |
82.9 |
9200*2690*3390 |
51200 |
CG260-16 |
★Remarks:
• Transport dimensions for gensets; components set up separately must be taken into consideration.
• According to ISO 3046/1 at U=0.4 kV,cos=1.0 for 50 Hz and methane number of MN-70 (MN-80 for some engine models) for natural gas.
• Exhaust gas cooled to 120°C for natural gas and 150°C (TCG2032 180°C) for biogas.
• NO ≤ 500 mg/Nm³; exhaust gas dry at 5 % O2.
• Data for special gas and dual gas operation on request.
Model |
COP |
Engine |
Bore*Stroke |
Displace |
Ratation |
Elec. |
Therm. |
Total |
Overall |
Weight |
(KW) |
Model |
(mm) |
ment |
Speed |
Eff. |
Eff. |
Eff. |
dimension |
(kg) |
|
(L) |
(rpm) |
(%) |
(%) |
(%) |
(L*W*H)(mm) |
|||||
EMW-400B6 |
400 |
TCG2016V08C / |
132*160 |
17.5 |
1800 |
41.6 |
43.2 |
84.8 |
3170*1490*2190 |
5120 |
CG132-8 |
||||||||||
EMW-600B6 |
600 |
TCG2016V12C / |
132*160 |
26.3 |
1800 |
41.4 |
43.7 |
85.1 |
3770*1490*2190 |
6260 |
CG132-12 |
||||||||||
EMW-800B6 |
800 |
TCG2016V16C / |
132*160 |
35 |
1800 |
41.7 |
43.3 |
85 |
4130*1490*2190 |
6780 |
CG132-16 |
||||||||||
EMW-1200B6 |
1200 |
TCG2020V12 / |
170*195 |
53.1 |
1500 |
41.8 |
43.8 |
85.6 |
5970*1790*2210 |
12850 |
CG170-12 |
||||||||||
EMW-1560B6 |
1560 |
TCG2020V16 / |
170*195 |
70.8 |
1500 |
41.4 |
43.9 |
85.3 |
6640*1790*2210 |
14850 |
CG170-16 |
||||||||||
EMW-2000B6 |
2000 |
TCG2020V20 / |
170*195 |
88.5 |
1500 |
42.6 |
43.3 |
85.9 |
7470*1710*2190 |
19400 |
CG170-20 |
||||||||||
EMW-3510B6 |
3510 |
TCG2032V16 / |
260*320 |
271.8 |
900 |
43.3 |
38.5 |
81.8 |
9420*2690*3390 |
53300 |
CG260-16 |
★Remarks:
• Transport dimensions for gensets; components set up separately must be taken into consideration.
• According to ISO 3046/1 at U=0.4 kV,cos=1.0 for 50 Hz and methane number of MN-70 (MN-80 for some engine models) for natural gas.
• Exhaust gas cooled to 120°C for natural gas and 150°C (TCG2032 180°C) for biogas.
• NO ≤ 500 mg/Nm³; exhaust gas dry at 5 % O2.
• Data for special gas and dual gas operation on request.